erj-145mech is right on the money. There are 5 GCU's, 2 near the left relay rack, and 2 on the right relay rack to control the engine generators. The last GCU for the APU is under the center floor board as you walk into the cockpit. You can control the voltage of the generators by turning the set screws located on the top of the boxes.
|